Documented range
Air-insulated MV switchgear
Incomers, feeders and transformer protection: define board functions and configuration.
Published rated voltages: 12 / 24 / 36 / 40.5 kV.
Tunisia · Türkiye
West African consultations must distinguish coastal markets from landlocked destinations. This hub connects Côte d’Ivoire, Senegal and Guinea with requirements in Mali, Burkina Faso and Niger. Documented MV levels vary, including within one country; country sources identify the location and period concerned.

A gateway port and a delivery destination are different inputs. For landlocked sites, describe transit, road movement and final heavy-equipment access. For 30 or 33 kV networks, compare maximum network voltage with switchgear classes and exact cable U0/U/Um markings. Describe heat, dust and maintenance at site level rather than treating the region as one environment.
15 / 30 kV
EDM-SA — Énergie du Mali
15 / 33 kV
CIE — Compagnie Ivoirienne d’Électricité ; CI-ENERGIES
6.6 / 30 kV
Senelec — Société nationale d’électricité du Sénégal
15 / 20 / 33 / 34.5 kV
SONABEL — Société nationale d’électricité du Burkina
20 / 33 kV
NIGELEC — Société nigérienne d’électricité
15 / 20 / 30 kV
EDG-SA — Électricité de Guinée
Values come from the cited sources, sometimes specific to a project or period. Confirm supply voltage, maximum network voltage and operator requirements before selecting equipment.
| Choose your project country | Documented voltage levels | Network counterpart |
|---|---|---|
| Mali | 15 / 30 kV | EDM-SA — Énergie du Mali |
| Côte d’Ivoire | 15 / 33 kV | CIE — Compagnie Ivoirienne d’Électricité ; CI-ENERGIES |
| Senegal | 6.6 / 30 kV | Senelec — Société nationale d’électricité du Sénégal |
| Burkina Faso | 15 / 20 / 33 / 34.5 kV | SONABEL — Société nationale d’électricité du Burkina |
| Niger | 20 / 33 kV | NIGELEC — Société nigérienne d’électricité |
| Guinea | 15 / 20 / 30 kV | EDG-SA — Électricité de Guinée |
Configurations are adapted from the Imperium catalogue verified for this version. Confirm the actual reference, documents and availability in the offer; local approval is not automatic.

Documented range
Incomers, feeders and transformer protection: define board functions and configuration.
Published rated voltages: 12 / 24 / 36 / 40.5 kV.

Documented range
Compact ring-distribution configurations; define switching and protection duties.
Published rated voltages: 12 / 24 / 36 kV. Reference catalogue uses SF6 technology.

Documented range
MV/LV transformation with liquid insulation and cooling; project-specific connections and siting.
Published range: 25–2,500 kVA; primary 3.3–36 kV. Agree actual model values.

Documented range
MV compartment, transformer and LV distribution in one assembly; coordinate civil and electrical interfaces.
Published MV classes: 12 / 24 / 36 kV; transformer 100–2,500 kVA depending on configuration.
Specify weights, dimensions, port, final site, lifting and origin/transport documents. Packing, service and timing depend on the shipment. An Incoterm needs its named place and version; FCA or DAP are options to agree, not universal terms. Check ISPM 15 for regulated raw wood packaging.
Prepare procurement and logisticsNo. Define transit, border crossings, route, unloading and final destination for the same shipment.
No. Check U0/U/Um markings, earthing and network requirements; catalogue inclusion does not replace validation.
Tell us about your application, site and technical constraints to prepare a useful equipment consultation.