Documented range
Air-insulated MV switchgear
Incomers, feeders and transformer protection: define board functions and configuration.
Published rated voltages: 12 / 24 / 36 / 40.5 kV.
West Africa
Electrical projects in Guinea may combine substantial industrial loads, handling equipment and pumping services. T Afrik Energy supports MV/LV equipment specification using actual site conditions. The applications below are illustrative uses, with no claim of completed work.

Documented voltage levels
15 / 20 / 30 kVNetwork counterpart
EDG-SA — Électricité de GuinéeEDG’s 2023 annual report documents 15 kV lines, new 20 kV feeders in Conakry and 30 kV distribution in other localities. This variety makes verification of the planned connection voltage and configuration essential. An industrial internal network may also have its own transformation and protection requirements. Provide delivery-point data, motor loads and operating profiles before selecting equipment. Where humidity, dust or corrosive exposure is significant, explicitly assess enclosure protection, ventilation and maintenance access. The documented national context should guide questions rather than replace site-specific electrical data.
The reference catalogue includes AIS and RMU classes 12, 24 and 36 kV, and AIS up to 40.5 kV. For nominal 30 or 33 kV networks, examine the 36 kV option against maximum voltage, insulation, current and fault constraints. A 24 kV class does not cover a nominal 30 kV network; 36 kV does not cover 66 kV. Cable U0/U/Um markings require separate validation.
EquipmentThe Port of Conakry identifies itself as Guinea’s principal commercial port. It is an entry point to assess for equipment shipments, with arrangements confirmed for the actual cargo. Port receiving and transport to the industrial installation should be planned as connected stages. Specify the final site, unit dimensions and weights, temporary storage needs and available unloading equipment. For motors or switchgear intended for existing buildings, check internal access and installation supports as well. A regional destination needs its own assessment of the onward road route and final receiving conditions.
Configurations are adapted from the Imperium catalogue verified for this version. Confirm the actual reference, documents and availability in the offer; local approval is not automatic.

Documented range
Incomers, feeders and transformer protection: define board functions and configuration.
Published rated voltages: 12 / 24 / 36 / 40.5 kV.

Documented range
Compact ring-distribution configurations; define switching and protection duties.
Published rated voltages: 12 / 24 / 36 kV. Reference catalogue uses SF6 technology.

Documented range
MV/LV transformation with liquid insulation and cooling; project-specific connections and siting.
Published range: 25–2,500 kVA; primary 3.3–36 kV. Agree actual model values.

Documented range
MV compartment, transformer and LV distribution in one assembly; coordinate civil and electrical interfaces.
Published MV classes: 12 / 24 / 36 kV; transformer 100–2,500 kVA depending on configuration.

Documented range
Distribute loads and priority circuits with an arrangement suited to operation and maintenance.
Fixed or withdrawable catalogue configurations; define assembly verification documentation.

Documented range
Pumps, fans and compressors: specify speed, torque, starting and service conditions.
Published voltage range: 1–11 kV. A motor cannot connect directly to every MV incomer.

Documented range
Copper or aluminium power connections; assess U0/U/Um, laying conditions and accessories together.
Published classes: 6/10 to 18/30 kV. Do not assume suitability for a 33 kV network without validation.
Distinguish the EDG interface from internal distribution and identify who reviews the technical arrangement. The dossier can request substation layouts, protection data, motor characteristics and relevant test reports. Guinea’s 2023 decree defines IGNM’s standardisation, quality and metrology responsibilities; applicable technical references should be checked in the project requirements. For conveyors or other industrial loads, specify operating cycles, starting conditions and coordinated stopping. Environmental suitability and access for servicing should form part of the equipment comparison, with acceptance managed through the project’s technical process.
Organise your technical dossierPossible applications, not completed T Afrik project references.
MV motors and power supplies for mineral conveyors and handling equipment.
IndustriesServicesSubstations and boards for crushing workshops and material processing installations.
IndustriesServicesPower distribution for pumps and auxiliary systems at industrial or port facilities.
IndustriesServicesEDG’s 2023 report also documents 15 and 20 kV. Confirm the actual level for the project’s locality and delivery point.
Describe humidity, dust, any corrosive exposure, temperature and the intended location. These details help define enclosures, ventilation and maintenance arrangements.
Sources checked on 9 October 2026
Specify weights, dimensions, port, final site, lifting and origin/transport documents. Packing, service and timing depend on the shipment. An Incoterm needs its named place and version; FCA or DAP are options to agree, not universal terms. Check ISPM 15 for regulated raw wood packaging.
Prepare procurement and logisticsTell us about your application, site and technical constraints to prepare a useful equipment consultation.