Documented range
Air-insulated MV switchgear
Incomers, feeders and transformer protection: define board functions and configuration.
Published rated voltages: 12 / 24 / 36 / 40.5 kV.
West Africa
For a Niger project, power requirements and site access should be defined together. T Afrik Energy supports enquiries for transformation, distribution and motor supplies serving industrial and pumping installations. The applications listed are illustrative examples.

Documented voltage levels
20 / 33 kVNetwork counterpart
NIGELEC — Société nigérienne d’électricitéARSE’s compilation updated in May 2024 describes NIGELEC distribution feeders mainly at 20 and 33 kV phase-to-phase. This definition does not replace specific feeder data or exclude particular configurations. For pumping or industrial connections, confirm the delivery level, capacity and protection requirements. Cable length, motor starting methods and changing loads may affect sizing. Also specify site temperature, dust exposure and backup arrangements where an interruption would affect the process or service. Equipment selection should follow these actual inputs rather than a country-wide voltage assumption.
The reference catalogue includes AIS and RMU classes 12, 24 and 36 kV, and AIS up to 40.5 kV. For nominal 30 or 33 kV networks, examine the 36 kV option against maximum voltage, insulation, current and fault constraints. A 24 kV class does not cover a nominal 30 kV network; 36 kV does not cover 66 kV. Cable U0/U/Um markings require separate validation.
EquipmentNiger is landlocked, so a maritime import requires a transit corridor and a final route to site. The World Bank’s May 2025 Lomé–Ouagadougou–Niamey document links the Port of Lomé to Niger through Burkina Faso. This supports assessment of a transport option, with crossing conditions checked for the shipment. A location beyond Niamey requires a separate review of the final journey. Unit weights, dimensions and unloading capabilities should be known before transport arrangements are selected, particularly for a transformer or a compact substation.
Configurations are adapted from the Imperium catalogue verified for this version. Confirm the actual reference, documents and availability in the offer; local approval is not automatic.

Documented range
Incomers, feeders and transformer protection: define board functions and configuration.
Published rated voltages: 12 / 24 / 36 / 40.5 kV.

Documented range
MV/LV transformation with liquid insulation and cooling; project-specific connections and siting.
Published range: 25–2,500 kVA; primary 3.3–36 kV. Agree actual model values.

Documented range
MV compartment, transformer and LV distribution in one assembly; coordinate civil and electrical interfaces.
Published MV classes: 12 / 24 / 36 kV; transformer 100–2,500 kVA depending on configuration.

Documented range
Distribute loads and priority circuits with an arrangement suited to operation and maintenance.
Fixed or withdrawable catalogue configurations; define assembly verification documentation.

Documented range
Prime or standby supply: assess loads, starting and siting before selecting capacity.
Published range: 0.5–3,550 kVA. Confirm the actual duty and offered rating.

Documented range
Pumps, fans and compressors: specify speed, torque, starting and service conditions.
Published voltage range: 1–11 kV. A motor cannot connect directly to every MV incomer.

Documented range
Copper or aluminium power connections; assess U0/U/Um, laying conditions and accessories together.
Published classes: 6/10 to 18/30 kV. Do not assume suitability for a 33 kV network without validation.
State whether equipment serves a NIGELEC connection, internal distribution or an independent supply. ARSE’s May 2024 compilation includes the network code and distribution rules; applicable project requirements should be confirmed with the relevant parties. ISO’s directory identifies ANMC as the national standards body. For motor feeders, request load data, starting characteristics and protection requirements. For pumping stations, add operating cycles, controls and restart conditions. These inputs establish a clear technical basis for comparing proposals and reviewing the final arrangement with the project team.
Organise your technical dossierPossible applications, not completed T Afrik project references.
Motor feeders, transformers and controls for drinking-water pumping stations.
IndustriesServicesPower distribution for irrigation installations with multiple pumps.
IndustriesServicesMV/LV substations and auxiliary supplies for cement manufacturing facilities.
IndustriesServicesARSE’s May 2024 compilation describes mainly 20 and 33 kV phase-to-phase. Confirm actual voltage and protection requirements for the connection.
The World Bank documents the Lomé–Ouagadougou–Niamey corridor in May 2025. The route, transit conditions and final journey must be checked for each shipment.
Sources checked on 9 October 2026
Specify weights, dimensions, port, final site, lifting and origin/transport documents. Packing, service and timing depend on the shipment. An Incoterm needs its named place and version; FCA or DAP are options to agree, not universal terms. Check ISPM 15 for regulated raw wood packaging.
Prepare procurement and logisticsTell us about your application, site and technical constraints to prepare a useful equipment consultation.