Skip to main content

IEC 62271 / IEC 60076 / IEEE C57 COMPLIANT POWER ASSETS

Industrial-Grade Electrical Equipment & Power Systems for African Infrastructure

Turnkey equipment procurement and integration across MV, HV, and utility-scale renewable systems. Fully compliant with IEC, IEEE, and local grid codes across Tunisia, North Africa, and regional power pools.

Transformers DeployedAcross Utility & Mining Grids
48,000+ kVA
Equipment ReliabilityField MTBF Operational Metric
99.7%
Certified Global OEMsNorth America, Europe, Asia
40+ Facilities
African Corridors ServedMaghreb, Sahel, Rift Valley
14+ Corridors
Showing 27 Equipment Classes
SECTION 011 kV – 40.5 kV Distribution

Medium Voltage Switchgear & RMU Systems

Primary and secondary distribution switchboards engineered for industrial facilities, utility distribution substations, and severe desert/tropical ambient environments.

PRIMARY DISTRIBUTIONIEC 62271-200

Air-Insulated Indoor Metal-Clad Switchgear (AIS)

Withdrawable vacuum or SF6 circuit breaker units with internal arc classification (IAC AFLR up to 40kA 1s), capacitive voltage indicators, and intelligent protection relay integration.

Rated Voltage
12 kV / 24 kV / 36 kV
Rated Current
630 A to 4,000 A
Short-Circuit
Up to 40 kA (3s)
IEC 62271-200IEC 62271-100STEG Approved
Verified through international supply network: Imperium specs
Request Tender SpecsFAT / SAT Ready
SECONDARY SUBSTATIONSIEC 62271-202

SF6 & Eco-Gas Ring Main Units (RMU)

Compact sealed stainless-steel tank ring main units featuring load break switches and circuit breaker feeder protection for urban rings, wind farms, and commercial buildings.

Rated Voltage
12 kV / 24 kV / 36 kV
Busbar Current
630 A Continuous
Protection
Self-Powered Relays
IEC 62271-102IEC 62271-200IP67 Tank
Verified through international supply network: Imperium specs
Request Tender SpecsFAT / SAT Ready
INDUSTRIAL DRIVESIEC 60947-4-1

Motor Control Centers & Soft-Starter Feeder Panels

Medium voltage motor starting systems incorporating vacuum contactors, bypass isolators, digital soft-starters, and variable frequency drives (VFDs) for mining pumps and compressors.

Operating Voltage
3.3 kV / 6.6 kV / 11 kV
Motor Rating
Up to 5,000 kW
Enclosure
NEMA 4 / IP54 Form 4b
IEC 60470IEEE 519IEC 60947
Request Tender SpecsFAT / SAT Ready
SECTION 02Oil-Immersed & Cast Resin

Power & Distribution Transformers

High-efficiency transformers manufactured with premium laser-cut core laminations, electrolytic copper windings, and advanced cooling options (ONAN / ONAF / OFAF).

UTILITY DISTRIBUTIONIEC 60076

Hermetically Sealed Oil Distribution Transformers

Maintenance-free hermetically sealed distribution units insulated with mineral oil or biodegradable synthetic ester fluid, engineered for high ambient temperatures up to 55°C.

Power Ratings
50 kVA to 3,150 kVA
Primary Voltage
10 kV to 36 kV
Eco-Design
Tier 2 EU 548/2014
IEC 60076-1EN 50588-1ISO 9001
Verified through international supply network: Imperium specs
Request Tender SpecsFAT / SAT Ready
INDOOR & COMMERCIALF1 / E2 / C2 CLASS

Cast Resin Dry-Type Transformers (CRT)

Moisture-proof, non-flammable, self-extinguishing epoxy resin insulated transformers ideal for hospitals, data centers, airports, and high-density commercial towers.

Power Ratings
100 kVA to 4,000 kVA
Thermal Class
Class F (155°C) / H
Protection
PT100 RTD Sensors
IEC 60076-11CEI 14-8Fire Behavior F1
Verified through international supply network: Imperium specs
Request Tender SpecsFAT / SAT Ready
SUBSTATION STEP-UPUp to 550 kV

Utility-Scale Primary Power Transformers

Large high-voltage generator step-up (GSU) and transmission autotransformers featuring on-load tap changers (OLTC), dissolved gas monitoring (DGA), and fiber-optic winding sensors.

Capacity Range
10 MVA to 250 MVA
Voltage Classes
66 kV / 90 kV / 150 kV / 225 kV
Testing
Full Type Tested KEMA / CESI
IEC 60076IEEE C57.12CIGRE Guidelines
Verified through international supply network: Imperium specs
Request Tender SpecsFAT / SAT Ready
SECTION 03Pre-Engineered & Packaged

Turnkey Substations & Modular Grids

Engineered containerized sub-stations, skid-mounted units, and mobile emergency substations designed for rapid deployment, harsh weather, and fast energization.

MODULAR DEPLOYMENTPlug-and-Play

Pre-Engineered Containerized Substations (E-Houses)

Heavy-gauge steel enclosures fully integrated with MV switchgear, LV distribution, DC battery banks, HVAC cooling, and fire suppression systems, factory-wired and tested.

Voltage Rating
Up to 36 kV
Thermal Rating
-20°C to +55°C Desert
Fire Resistance
EI60 / EI120 Rated
IEC 62271-202NFPA 850CSC Certified
Verified through international supply network: Imperium specs
Request Tender SpecsFAT / SAT Ready
GRID RESILIENCERapid Dispatch

Trailer-Mounted Mobile Emergency Substations

Complete multi-axle trailer-mounted high-voltage sub-stations providing temporary power bypass during maintenance, grid expansion, or disaster recovery.

Configuration
HV Incomer + Trafo + MV Feeder
Rating
10 MVA to 40 MVA
Mobility
Off-Road Heavy Tractor Compatible
IEC 60076ISO 1496DOT / African Road Approved
Verified through international supply network: Imperium specs
Request Tender SpecsFAT / SAT Ready
HIGH DENSITYIEC 62271-203

Gas-Insulated Indoor Substations (GIS Packages)

Compact SF6 gas-insulated switchgear installations delivering maximum operational reliability in congested coastal cities and industrial plants with space limitations.

Voltage Range
72.5 kV to 245 kV
Footprint Savings
Up to 85% vs AIS
Gas Leakage
< 0.1% per Annum
IEC 62271-203CIGRE 23.10ISO 14001
Verified through international supply network: Imperium specs
Request Tender SpecsFAT / SAT Ready
SECTION 04Form 4b Up to 6,300 A

Low Voltage Distribution & Motor Control

Heavy-duty low-voltage switchboards, intelligent motor control centers, and power quality conditioning panels conforming to IEC 61439-1/2.

POWER DISTRIBUTIONIEC 61439-2

Form 4b Heavy Industrial Main Distribution Boards

Fully compartmentalized modular power switchboards with withdrawable air circuit breakers (ACB), molded-case breakers (MCCB), and copper busbar arrangements up to 6300A.

Rated Voltage
400 V / 690 V AC
Short-Time Current
Up to 100 kA (1s)
Internal Separation
Form 4b Type 7
IEC 61439-1IEC 61439-2CE Marking
Request Tender SpecsFAT / SAT Ready
AUTOMATION & SCADAProfinet / Modbus

Intelligent Motor Control Centers (iMCC)

Draw-out motor feeder modules equipped with electronic motor protection relays, energy meters, harmonic filtration, and Ethernet communications for remote SCADA telemetry.

Motor Capacity
0.37 kW to 400 kW
Protocols
IEC 61850 / Modbus / Profinet
Interchangeability
Full Drawout under load
IEC 60947IEC 61439ISA 101
Request Tender SpecsFAT / SAT Ready
POWER QUALITYHarmonic Mitigation

Automatic Power Factor Correction & Active Harmonic Filters

Detuned capacitor banks and IGBT-based active harmonic filters (AHF) that eliminate utility reactive penalty fees, restore sinusoidal waveform, and protect sensitive loads.

Reactive Power
50 kvar to 1,200 kvar
Harmonic Filtering
Up to 50th Harmonic Order
Response Time
< 5ms Dynamic Control
IEEE 519-2014IEC 61000-3-4IEC 61921
Request Tender SpecsFAT / SAT Ready
SECTION 05Prime, Standby & Continuous

Industrial Power Generation & Heavy Motors

Robust thermal power generation units and heavy-duty industrial electric motors engineered for uninterrupted operations in remote mining, utilities, and factories.

CONTINUOUS BASELOADISO 8528

Heavy-Duty Prime & Standby Diesel Generator Sets

Skid-mounted and sound-attenuated containerized diesel power generators powered by tier-1 global engines, equipped with digital paralleling controllers and fuel filtration.

Power Output
250 kVA to 3,500 kVA
Engine Speed
1,500 RPM (50 Hz)
Fuel System
Dual Filtration & Day Tank
ISO 8528-1ISO 3046IEC 60034
Verified through international supply network: Imperium specs
Request Tender SpecsFAT / SAT Ready
ENERGY EFFICIENCYNatural Gas & Biogas

Gas-Fired Combined Heat & Power (CHP) Generation Skids

High-efficiency reciprocating gas engines generating both base-load electrical power and hot water / steam for industrial chemical, cement, and food processing plants.

Electrical Output
500 kWe to 4,500 kWe
Total Efficiency
Up to 90% Combined
Fuel Source
Pipeline Gas / Associated Gas
ISO 9001EU Stage V ReadyTA-Luft Low Emission
Verified through international supply network: Imperium specs
Request Tender SpecsFAT / SAT Ready
HEAVY DRIVE SYSTEMSSquirrel Cage & Slip-Ring

Severe-Duty Medium Voltage Induction Motors

Cast-iron severe-duty induction motors for heavy conveyors, ball mills, water intake pumps, and gas compressors operating in dusty, high-temperature Saharan conditions.

Voltage Ratings
3.3 kV / 6.6 kV / 11 kV
Output Power
200 kW to 8,000 kW
Cooling Method
IC411 (TEFC) / IC611 (CACA)
IEC 60034-1NEMA MG-1ATEX / IECEx Options
Verified through international supply network: Imperium specs
Request Tender SpecsFAT / SAT Ready
SECTION 06Underground & Overhead Transmission

Medium / High Voltage Cables & Conductors

High-conductivity copper and aluminum power transmission cables with cross-linked polyethylene (XLPE) insulation, metallic screening, and heavy armoring.

GRID TRANSMISSIONIEC 60502 / IEC 60840

Underground Armored XLPE MV & HV Power Cables

Single-core and three-core copper or aluminum conductor cables with dry-cured triple extrusion XLPE insulation, lead/aluminum sheath, and anti-termite outer sheath.

Voltage Range
10 kV to 220 kV
Conductor Size
50 mm² to 1,200 mm²
Armoring
Corrugated Al / Steel Tape / Wire
IEC 60502-2IEC 60840CENELEC HD 620
Verified through international supply network: Imperium specs
Request Tender SpecsFAT / SAT Ready
TRANSMISSION CORRIDORSHigh Ampacity

Overhead Aluminum Conductors (ACSR, AAAC, HTLS)

Bare overhead transmission conductors designed for high tensile strength, minimal sag across long spans, and high thermal capacity in desert ambient temperatures.

Alloy Types
ACSR, AAAC, ACAR, HTLS
Span Capabilities
Long River & Mountain Crossings
Corrosion Protection
Greased Core Options
IEC 61089ASTM B232BS 215
Verified through international supply network: Imperium specs
Request Tender SpecsFAT / SAT Ready
OFFSHORE & CROSS-BORDERHVDC & HVAC Subsea

Subsea & Armored High-Voltage Transmission Cables

High-reliability subsea cables with integrated fiber-optic sensing for cross-border interconnections, offshore energy platforms, and island power transmission.

Voltages
33 kV to 400 kV
Armoring
Heavy Galvanized Steel Wire
Sensors
Distributed Temperature Sensing
CIGRE 490CIGRE 623IEC 60840
Verified through international supply network: Imperium specs
Request Tender SpecsFAT / SAT Ready
SECTION 07Air-Insulated Switchyard 72.5 kV – 400 kV

High Voltage Yard & Substation Apparatus

Primary high-voltage yard equipment delivering maximum dielectric withstand, seismic resistance, and extreme ambient performance for outdoor grid substations.

PRIMARY PROTECTIONIEC 62271-100

Outdoor Live-Tank & Dead-Tank SF6 Circuit Breakers

High-performance sulfur hexafluoride (SF6) gas circuit breakers equipped with spring operating mechanisms, porcelain or composite silicone insulators, and density monitors.

Rated Voltage
72.5 kV to 400 kV
Interrupting Current
Up to 50 kA
Operating Duty
O - 0.3s - CO - 3min - CO
IEC 62271-100IEEE C37.04ANSI Approved
Verified through international supply network: Imperium specs
Request Tender SpecsFAT / SAT Ready
SWITCHYARD ISOLATIONIEC 62271-102

Center-Break & Pantograph Disconnectors with Earth Switches

Motorized and manual disconnector switches with integrated earth switches, silver-plated copper contacts, and mechanical interlocks for safe maintenance switching.

Voltage Ratings
72.5 kV to 400 kV
Current Ratings
1,250 A to 4,000 A
Drive Mechanism
Motor-Operated 110V/220V DC
IEC 62271-102IEC 60694
Verified through international supply network: Imperium specs
Request Tender SpecsFAT / SAT Ready
METERING & PROTECTIONClass 0.2s Accuracy

Surge Arresters & Instrument Transformers (CT / PT)

Oil-filled or SF6 instrument transformers providing ultra-accurate current and voltage metering for revenue calculation and protective relay tripping, paired with polymer arresters.

Accuracy Class
0.2S / 0.5 / 5P20 / 10P20
Arrester Discharge
Class 4 (10 kA / 20 kA)
Creepage Distance
31 mm/kV Severe Pollution
IEC 61869-1/2/3IEC 60099-4
Verified through international supply network: Imperium specs
Request Tender SpecsFAT / SAT Ready
SECTION 08Terminations, Busbars & Earthing

Electrical Accessories & Infrastructure Hardware

High-grade auxiliary components essential for the safety, longevity, and electrical continuity of medium and high-voltage transmission networks.

CABLE ACCESSORIESCENELEC HD 629

Cold-Shrink & Heat-Shrink Cable Termination & Joint Kits

Pre-expanded silicone rubber cold-shrink indoor and outdoor terminations with integrated stress control, geometric deflector tubes, and waterproof sealing mastic.

Voltage Range
11 kV to 72.5 kV
Conductor Size
25 mm² to 1,000 mm²
Environment
UV, Saline & Desert Proof
IEC 60502-4CENELEC HD 629.1IEEE 48
Request Tender SpecsFAT / SAT Ready
POWER TRANSMISSIONCompact Sandwich Design

Copper & Aluminum Busduct / Busbar Trunking Systems

Sandwich-type insulated busbar trunking systems for high-current generator links, transformer-to-switchgear connections, and industrial riser distributions.

Current Range
800 A to 6,300 A
Ingress Protection
IP55 / IP68 Cast Resin
Conductor
99.99% Electrolytic Copper
IEC 61439-6UL 857KEMA Tested
Request Tender SpecsFAT / SAT Ready
SAFETY SYSTEMSIEEE 80 Compliant

Substation Grounding, Earthing Hardware & Lightning Protection

Exothermic welding molds, copper-bonded ground rods, tinned copper grounding conductors, and early streamer emission (ESE) air terminals for substation lightning protection.

Bonding Rods
254 Micron Copper Coating
Design Method
IEEE 80 Step & Touch Potential
Standards
NFC 17-102 / IEC 62305
IEEE 80IEC 62305BS 7430
Request Tender SpecsFAT / SAT Ready
SECTION 09Solar PV, Hybrid & Storage

Utility Clean Energy & Battery Storage (BESS)

Utility-scale battery energy storage systems, skid-mounted central inverter stations, and balance-of-systems engineered for solar farms and grid stabilization across Africa.

ENERGY STORAGEGrid-Scale Storage

Utility Containerized Liquid-Cooled LFP Battery Systems

Turnkey 20ft and 40ft energy storage containers incorporating high-safety lithium iron phosphate (LFP) cells, multi-stage BMS, aerosol fire suppression, and intelligent HVAC.

Energy Capacity
2.5 MWh to 5.0 MWh / Container
Charge/Discharge Rate
0.5C to 1C Utility Cycling
Cycle Life
6,000+ Cycles at 80% DoD
UL 9540UL 9540AIEC 62933UN 38.3
Request Tender SpecsFAT / SAT Ready
SOLAR PV INFRASTRUCTURE1500 V DC Architecture

Central Inverter Skid Stations for Solar PV

Pre-packaged outdoor skid stations combining high-efficiency 1500V central inverters, oil-immersed step-up transformers, and medium-voltage switchgear for utility solar plants.

Inverter Power
3.125 MW to 6.25 MW Skid
Max Efficiency
99.0% Euro Efficiency
Grid Support
Low Voltage Ride-Through (LVRT)
IEC 62109-1/2IEEE 1547VDE-AR-N 4110/4120
Request Tender SpecsFAT / SAT Ready
BALANCE OF SYSTEM1500 V DC Protection

Solar PV Balance of Systems (BoS) Combiner Boxes & Monitoring

IP66 polycarbonate and steel array junction boxes equipped with 1500V DC fuses, surge arresters, disconnector switches, and string-level current monitoring sensors.

String Inputs
16 to 32 Strings / Box
Protection
Type II DC Surge Arresters
Communications
RS485 / Modbus RTU
IEC 61439-2IEC 60269-6UL 1741
Request Tender SpecsFAT / SAT Ready

Engineering Packets & SLD Submittals

Need Project-Specific Tender Packets & SLD Clearings?

Our factory-authorized engineering desk compiles comprehensive technical dossiers with single-line diagrams (SLD), short-circuit calculations, and equipment schedules aligned with STEG, GECOL, and international utility standards.

Request Engineering Dossier

Rigorous Quality Governance

Pan-African FAT, Factory Inspection & Port Clearance

Stringent protocols for OEM defect elimination, transport customs clearance, and energization readiness.

01

Factory Acceptance Testing (FAT) & 3rd-Party Witnessing

T AFRIK coordinates certified third-party testing witnessing at OEM testing bays prior to dispatch. Protocols encompass full dielectric withstand, lightning impulse testing, temperature rise tests, partial discharge (PD) measurements, and acoustic sound pressure tests in compliance with IEC 60076 and IEC 62271.

02

Regulatory Compliance & Regional Grid Standards

Full technical alignment with North African and Pan-African transmission codes: STEG (Tunisia), GECOL (Libya), SONELGAZ (Algeria), CIE (Côte d'Ivoire), and GRIDCo (Ghana). We ensure every apparatus complies with local insulation coordination and short-circuit withstand levels.

03

Direct African Port Clearance & Off-Road Heavy-Haul Staging

Seamless multimodal clearance through key maritime gateways (Port of Radès, Sfax, Bizerte, Misrata, and Abidjan). Our logistics desk handles specialized multi-axle hydraulic trailers, route surveys, bridge load certifications, and customs bonded clearances directly to remote substation pads.

Technical Procurement Desk

Submit Your Tender RFQ or Equipment Specs

Our factory-authorized engineering team will review your single-line diagram (SLD), delivery specifications, and project timeline within 24 business hours.