Documented range
Gas-insulated compact RMUs
Compact ring-distribution configurations; define switching and protection duties.
Published rated voltages: 12 / 24 / 36 kV. Reference catalogue uses SF6 technology.
West Africa
For an industrial project in Mali, equipment selection starts with the installation’s power requirements and the final route to site. T Afrik Energy supports MV/LV equipment enquiries. The applications below illustrate possible uses and do not represent completed projects.

Documented voltage levels
15 / 30 kVNetwork counterpart
EDM-SA — Énergie du MaliThe World Bank’s March 2019 MESIP document describes EDM-SA networks at 15 and 30 kV in Bamako. These documented levels provide a starting point; the actual feeder and supply substation must be checked. An industrial connection, a peripheral extension or an independent installation may require a different arrangement. Before selecting an RMU, transformer or MV cable, establish the delivery voltage, required power, fault levels and protection scheme. Temperature, dust exposure and maintenance access also influence equipment specifications.
The reference catalogue includes AIS and RMU classes 12, 24 and 36 kV, and AIS up to 40.5 kV. For nominal 30 or 33 kV networks, examine the 36 kV option against maximum voltage, insulation, current and fault constraints. A 24 kV class does not cover a nominal 30 kV network; 36 kV does not cover 66 kV. Cable U0/U/Um markings require separate validation.
EquipmentMali is landlocked, so an equipment shipment needs both transit planning and a road route to the receiving site. Mali Customs identifies the Dakar–Bamako corridor in its November 2025 communication. This route can be assessed for a shipment, with crossing conditions checked when the offer is prepared. For a transformer or compact substation, specify transport dimensions, weight, the receiving location and available unloading equipment. Delivery in Bamako and delivery to a more remote installation require different assessments of the final road journey.
Configurations are adapted from the Imperium catalogue verified for this version. Confirm the actual reference, documents and availability in the offer; local approval is not automatic.

Documented range
Compact ring-distribution configurations; define switching and protection duties.
Published rated voltages: 12 / 24 / 36 kV. Reference catalogue uses SF6 technology.

Documented range
MV/LV transformation with liquid insulation and cooling; project-specific connections and siting.
Published range: 25–2,500 kVA; primary 3.3–36 kV. Agree actual model values.

Documented range
MV compartment, transformer and LV distribution in one assembly; coordinate civil and electrical interfaces.
Published MV classes: 12 / 24 / 36 kV; transformer 100–2,500 kVA depending on configuration.

Documented range
Distribute loads and priority circuits with an arrangement suited to operation and maintenance.
Fixed or withdrawable catalogue configurations; define assembly verification documentation.

Documented range
Prime or standby supply: assess loads, starting and siting before selecting capacity.
Published range: 0.5–3,550 kVA. Confirm the actual duty and offered rating.

Documented range
Pumps, fans and compressors: specify speed, torque, starting and service conditions.
Published voltage range: 1–11 kV. A motor cannot connect directly to every MV incomer.

Documented range
Copper or aluminium power connections; assess U0/U/Um, laying conditions and accessories together.
Published classes: 6/10 to 18/30 kV. Do not assume suitability for a 33 kV network without validation.
A Mali enquiry should state whether the equipment will connect to EDM-SA or form part of a private installation. The owner and design consultant can then request appropriate protection data, connection drawings and tests. ISO identifies AMANORM as the national standards body; applicable requirements should be checked against the project specification and with the relevant parties. For a remote site, also define spares, available maintenance skills and any generator integration. The technical proposal must be reviewed and accepted within the project’s own approval process.
Organise your technical dossierPossible applications, not completed T Afrik project references.
Irrigation pumping and power distribution for agricultural pumping stations.
IndustriesServicesMotors, LV boards and power supply for rice milling and processing units.
IndustriesServicesMV/LV substations and backup power for auxiliary facilities at mining sites.
IndustriesServicesMESIP sources document 15 and 30 kV in Bamako. Confirm the delivery voltage and network data with the connection authority before final equipment selection.
Provide the final location, equipment weight and transport dimensions, vehicle access and lifting arrangements. The route and transit conditions need to be assessed with the carrier for that shipment.
Sources checked on 9 October 2026
Specify weights, dimensions, port, final site, lifting and origin/transport documents. Packing, service and timing depend on the shipment. An Incoterm needs its named place and version; FCA or DAP are options to agree, not universal terms. Check ISPM 15 for regulated raw wood packaging.
Prepare procurement and logisticsTell us about your application, site and technical constraints to prepare a useful equipment consultation.