Documented range
Air-insulated MV switchgear
Incomers, feeders and transformer protection: define board functions and configuration.
Published rated voltages: 12 / 24 / 36 / 40.5 kV.
West Africa
Industrial electrical equipment for Burkina Faso should be assessed together with its connection and inland transport route. T Afrik Energy supports enquiries for substations, distribution and motor supplies. The sectors below illustrate potential applications.

Documented voltage levels
15 / 20 / 33 / 34.5 kVNetwork counterpart
SONABEL — Société nationale d’électricité du BurkinaThe ministry’s January 2026 SOLEER notice describes 15, 20, 33 and 34.5 kV distribution in the network supervised by SONABEL. This provisional document provides network context; the four values are not interchangeable or applicable to every delivery point. Confirm site voltage, neutral arrangements and fault levels before selecting switchgear, transformers or cables. For motor installations or several workshops, also provide load profiles and simultaneous starts. Heat, dust exposure and maintenance arrangements should inform the substation layout and equipment access.
The reference catalogue includes AIS and RMU classes 12, 24 and 36 kV, and AIS up to 40.5 kV. For nominal 30 or 33 kV networks, examine the 36 kV option against maximum voltage, insulation, current and fault constraints. A 24 kV class does not cover a nominal 30 kV network; 36 kV does not cover 66 kV. Cable U0/U/Um markings require separate validation.
EquipmentBurkina Faso requires inland transport after equipment arrives by sea. The Port of Abidjan’s 2024 report documents transit to the country, supporting assessment of that entry point. The chosen route must still be checked for each shipment and final destination. State whether receiving will take place in Ouagadougou, Bobo-Dioulasso or directly at another site. Compact substation dimensions, transformer weight and access to the receiving platform may require different transport arrangements. The carrier and site team should assess the final journey and unloading requirements together.
Configurations are adapted from the Imperium catalogue verified for this version. Confirm the actual reference, documents and availability in the offer; local approval is not automatic.

Documented range
Incomers, feeders and transformer protection: define board functions and configuration.
Published rated voltages: 12 / 24 / 36 / 40.5 kV.

Documented range
Compact ring-distribution configurations; define switching and protection duties.
Published rated voltages: 12 / 24 / 36 kV. Reference catalogue uses SF6 technology.

Documented range
MV/LV transformation with liquid insulation and cooling; project-specific connections and siting.
Published range: 25–2,500 kVA; primary 3.3–36 kV. Agree actual model values.

Documented range
MV compartment, transformer and LV distribution in one assembly; coordinate civil and electrical interfaces.
Published MV classes: 12 / 24 / 36 kV; transformer 100–2,500 kVA depending on configuration.

Documented range
Distribute loads and priority circuits with an arrangement suited to operation and maintenance.
Fixed or withdrawable catalogue configurations; define assembly verification documentation.

Documented range
Prime or standby supply: assess loads, starting and siting before selecting capacity.
Published range: 0.5–3,550 kVA. Confirm the actual duty and offered rating.

Documented range
Pumps, fans and compressors: specify speed, torque, starting and service conditions.
Published voltage range: 1–11 kV. A motor cannot connect directly to every MV incomer.

Documented range
Copper or aluminium power connections; assess U0/U/Um, laying conditions and accessories together.
Published classes: 6/10 to 18/30 kV. Do not assume suitability for a 33 kV network without validation.
Request a proposal based on the actual SONABEL connection or private installation. The technical dossier can compare switchgear functions, transformer losses, insulation levels and useful monitoring devices. ISO identifies ABNORM as the national standards body; the specification should define expected technical references and required reviews. For production workshops, provide operating cycles and controlled shutdown needs. At remote sites, spares availability, component access and local maintenance capabilities become practical comparison criteria. Proposed equipment should be reviewed against these requirements before the supply configuration is finalised.
Organise your technical dossierPossible applications, not completed T Afrik project references.
Motor supplies and LV distribution for cotton ginning plants.
IndustriesServicesSubstations and boards for oilseed pressing and oil production units.
IndustriesServicesPower for pumps, workshops and auxiliary installations at gold mining sites.
IndustriesServicesThe January 2026 SOLEER notice documents 15, 20, 33 and 34.5 kV in the network supervised by SONABEL. The actual connection point determines the equipment voltage.
The port’s 2024 report documents this transit. The route, crossing conditions and onward transport to site must be confirmed for the shipment.
Sources checked on 9 October 2026
Specify weights, dimensions, port, final site, lifting and origin/transport documents. Packing, service and timing depend on the shipment. An Incoterm needs its named place and version; FCA or DAP are options to agree, not universal terms. Check ISPM 15 for regulated raw wood packaging.
Prepare procurement and logisticsTell us about your application, site and technical constraints to prepare a useful equipment consultation.