Documented range
Air-insulated MV switchgear
Incomers, feeders and transformer protection: define board functions and configuration.
Published rated voltages: 12 / 24 / 36 / 40.5 kV.
Tunisia · Türkiye
Kenya, Tanzania, Ethiopia and Madagascar have distinct import routes and networks. This hub connects maritime or transit gateways with equipment selection. Madagascar is grouped here for Indian Ocean trade while keeping its island context separate from continental corridors.

An 11/33 kV network, a documented 15 kV feeder and local 20 kV distribution should not receive one default specification. Switchgear, transformers and motors must match their diagram functions. Inland sites need transport information beyond the maritime terminal. Madagascar requires an island-specific port-to-site assessment. Confirm connection data and import rules with each country’s relevant parties.
Values come from the cited sources, sometimes specific to a project or period. Confirm supply voltage, maximum network voltage and operator requirements before selecting equipment.
| Choose your project country | Documented voltage levels | Network counterpart |
|---|---|---|
| Madagascar | 20 kV | JIRAMA — Jiro sy Rano Malagasy |
| Ethiopia | 15 / 33 kV | EEU — Ethiopian Electric Utility; EEP — Ethiopian Electric Power |
| Kenya | 11 / 33 kV | Kenya Power and Lighting Company — Kenya Power |
| Tanzania | 11 / 33 kV | TANESCO — Tanzania Electric Supply Company Limited (mainland) |
Configurations are adapted from the Imperium catalogue verified for this version. Confirm the actual reference, documents and availability in the offer; local approval is not automatic.

Documented range
Incomers, feeders and transformer protection: define board functions and configuration.
Published rated voltages: 12 / 24 / 36 / 40.5 kV.

Documented range
Compact ring-distribution configurations; define switching and protection duties.
Published rated voltages: 12 / 24 / 36 kV. Reference catalogue uses SF6 technology.

Documented range
MV/LV transformation with liquid insulation and cooling; project-specific connections and siting.
Published range: 25–2,500 kVA; primary 3.3–36 kV. Agree actual model values.

Documented range
MV compartment, transformer and LV distribution in one assembly; coordinate civil and electrical interfaces.
Published MV classes: 12 / 24 / 36 kV; transformer 100–2,500 kVA depending on configuration.
Specify weights, dimensions, port, final site, lifting and origin/transport documents. Packing, service and timing depend on the shipment. An Incoterm needs its named place and version; FCA or DAP are options to agree, not universal terms. Check ISPM 15 for regulated raw wood packaging.
Prepare procurement and logisticsDefine voltage class, transformer, protection and installation conditions for the actual network.
Transit, customs, inland movement and receiving arrangements are also needed. Timing depends on shipment and site.
Tell us about your application, site and technical constraints to prepare a useful equipment consultation.