
Documented range
Air-insulated MV switchgear
Incomers, feeders and transformer protection: define board functions and configuration.
Published rated voltages: 12 / 24 / 36 / 40.5 kV.
East Africa and the Indian Ocean
Electrical projects in Tanzania may serve mining, agricultural processing or port logistics. TANESCO and Tanzania Ports Authority publications provide distinct examples around Geita, Mtwara and Dar es Salaam. Transformation and distribution choices should follow the actual process, whether motor loads, auxiliaries, handling or storage. An equipment enquiry should identify the location and connection operator from the outset, because mainland Tanzania and Zanzibar require their respective network information.

Documented voltage levels
11 / 33 kVNetwork counterpart
TANESCO — Tanzania Electric Supply Company Limited (mainland)EWURA’s FY2023/24 regulatory report identifies 11 and 33 kV MV levels within TANESCO’s distribution activities, providing recent evidence for mainland Tanzania. These figures do not establish an individual site’s connection voltage. For manufacturing or mining, identify the supply substation, available feeder, motor loads and protection interfaces. Zanzibar projects need their own operator and local network data; mainland specifications should not be assumed to settle a connection elsewhere.
The reference catalogue includes AIS and RMU classes 12, 24 and 36 kV, and AIS up to 40.5 kV. For nominal 30 or 33 kV networks, examine the 36 kV option against maximum voltage, insulation, current and fault constraints. A 24 kV class does not cover a nominal 30 kV network; 36 kV does not cover 66 kV. Cable U0/U/Um markings require separate validation.
EquipmentTanzania Ports Authority identifies Dar es Salaam as the principal port and a gateway serving several landlocked neighbours. Its ports masterplan also describes Tanga and Mtwara; Mtwara’s context includes oil and gas project cargo and cashew exports. Port selection should follow the construction-site destination and the equipment’s handling requirements. Enquiries for northern Tanzania, Dar es Salaam or the Mtwara area should therefore specify the intended inland route and receiving arrangements.
Configurations are adapted from the Imperium catalogue verified for this version. Confirm the actual reference, documents and availability in the offer; local approval is not automatic.

Documented range
Incomers, feeders and transformer protection: define board functions and configuration.
Published rated voltages: 12 / 24 / 36 / 40.5 kV.

Documented range
MV/LV transformation with liquid insulation and cooling; project-specific connections and siting.
Published range: 25–2,500 kVA; primary 3.3–36 kV. Agree actual model values.

Documented range
MV compartment, transformer and LV distribution in one assembly; coordinate civil and electrical interfaces.
Published MV classes: 12 / 24 / 36 kV; transformer 100–2,500 kVA depending on configuration.

Documented range
Distribute loads and priority circuits with an arrangement suited to operation and maintenance.
Fixed or withdrawable catalogue configurations; define assembly verification documentation.

Documented range
Pumps, fans and compressors: specify speed, torque, starting and service conditions.
Published voltage range: 1–11 kV. A motor cannot connect directly to every MV incomer.

Documented range
Copper or aluminium power connections; assess U0/U/Um, laying conditions and accessories together.
Published classes: 6/10 to 18/30 kV. Do not assume suitability for a 33 kV network without validation.
EWURA’s published distribution code covers connection requirements, metering, information exchange and network performance. Match it to the TANESCO specifications applicable to the project. The FY2022/23 audit report describes a 33 kV industrial connection for Geita Gold Mine with a 33/11 kV customer substation; it does not confirm present completion. For a comparable enquiry, provide upstream and downstream arrangements, motor capacities and maintenance conditions before defining the electrical equipment package.
Organise your technical dossierPossible applications, not completed T Afrik project references.
Geita-area mining installation: MV switchgear and cables, transformation and motor feeders suited to the process and studied connection.
IndustriesServicesCashew processing around Mtwara: supplies for preparation lines, packaging equipment and auxiliary services.
IndustriesServicesDar es Salaam port facility: MV/LV distribution for handling equipment, technical buildings and logistics services, with circuits allocated by function.
IndustriesServicesThe evidence here concerns TANESCO’s mainland activities. A Zanzibar project needs its own operator, connection point and local network data.
It records one industrial arrangement in a dated report. Your mine’s voltage, available capacity and transformer configuration must be established for its particular connection.
Sources checked on 9 October 2026
Specify weights, dimensions, port, final site, lifting and origin/transport documents. Packing, service and timing depend on the shipment. An Incoterm needs its named place and version; FCA or DAP are options to agree, not universal terms. Check ISPM 15 for regulated raw wood packaging.
Prepare procurement and logisticsTell us about your application, site and technical constraints to prepare a useful equipment consultation.