Documented range
Air-insulated MV switchgear
Incomers, feeders and transformer protection: define board functions and configuration.
Published rated voltages: 12 / 24 / 36 / 40.5 kV.
Tunisia · Türkiye
Cameroon and Chad require coordination between electrical connection and inland transport. Cameroon’s network data must not be transferred to Chad. This hub organises consultations around locally documented levels and the route from maritime gateway to industrial site.

Define destination, transit and import responsibilities before comparing freight. A 15 or 30 kV distribution connection needs its own protection design; an MV motor cannot be chosen from the site’s incomer voltage alone. For remote loads, document operation, maintenance and any standby supply. Identify the current operator and specification version rather than reusing an old reference without context.
Values come from the cited sources, sometimes specific to a project or period. Confirm supply voltage, maximum network voltage and operator requirements before selecting equipment.
Configurations are adapted from the Imperium catalogue verified for this version. Confirm the actual reference, documents and availability in the offer; local approval is not automatic.

Documented range
Incomers, feeders and transformer protection: define board functions and configuration.
Published rated voltages: 12 / 24 / 36 / 40.5 kV.

Documented range
Compact ring-distribution configurations; define switching and protection duties.
Published rated voltages: 12 / 24 / 36 kV. Reference catalogue uses SF6 technology.

Documented range
MV/LV transformation with liquid insulation and cooling; project-specific connections and siting.
Published range: 25–2,500 kVA; primary 3.3–36 kV. Agree actual model values.

Documented range
MV compartment, transformer and LV distribution in one assembly; coordinate civil and electrical interfaces.
Published MV classes: 12 / 24 / 36 kV; transformer 100–2,500 kVA depending on configuration.
Specify weights, dimensions, port, final site, lifting and origin/transport documents. Packing, service and timing depend on the shipment. An Incoterm needs its named place and version; FCA or DAP are options to agree, not universal terms. Check ISPM 15 for regulated raw wood packaging.
Prepare procurement and logisticsOperators, network characteristics and project documents differ. Logistics proximity does not create one electrical standard.
Provide weights, dimensions and lifting points, site access and unloading equipment. Agree the route and responsibilities.
Tell us about your application, site and technical constraints to prepare a useful equipment consultation.